Product Model
734-176/108-000

Selling Points
- 1Angled Solder Pins for Versatile Mounting
- 2100% Mismating Protection for Reliable Connections
- 3Threaded Flange for Secure Locking
- 416-Pole Configuration for Multiple Connections
- 5Light Gray Color and Polyamide Insulation for Durability
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Parameter | Value | Parameter | Value |
---|---|---|---|
Safety information | TheMCS – MULTI CONNECTION SYSTEMincludes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load.When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure header pins, which can be touched, are not live when unmated. | Variants: | Other pole numbers |
Total number of potentials | 16 | Number of connection types | 1 |
Number of levels | 1 | Pin spacing | 3.5?mm?/ 0.138?inches |
Width | 65.5?mm?/ 2.579?inches | Height | 12.3?mm?/ 0.484?inches |
Height from the surface | 8.5?mm?/ 0.335?inches | Depth | 10.3?mm?/ 0.406?inches |
Solder pin length | 3.8mm | Solder pin dimensions | 1 x 1?mm |
Drilled hole diameter with tolerance | 1.4(+0.1)mm | Variable coding | Yes |
Anti-rotation protection | Yes | Contact type (pluggable connector) | Male connector/plug |
Connector (connection type) | for PCB | Mismating protection | Yes |
Plugging without loss of pin spacing | No | Mating direction to the PCB | 0° |
Locking of plug-in connection | Threaded flange | PCB contact | THT |
Solder pin arrangement | over the entire male connector (in-line) | Number of solder pins per potential | 1 |
Note (material data) | Information on material specifications can be found here | Color | light gray |
Material group | I | Insulation material (main housing) | Polyamide (PA66) |
Flammability class per UL94 | V0 | Contact material | Electrolytic copper (ECu) |
Contact plating | Tin | Fire load | 0.068MJ |
Weight | 2.7g | Limit temperature range | -60 … +100?°C |
Processing temperature | -35 … +60?°C | Product Group | 3 (Multi Conn. System) |
eCl@ss 10.0 | 27-44-04-02 | eCl@ss 9.0 | 27-44-04-02 |
ETIM 9.0 | EC002637 | ETIM 8.0 | EC002637 |
ECCN | NO US CLASSIFICATION | PU (SPU) | 50?pcs |
Packaging type | box | Country of origin | PL |
GTIN | 4045454683139 | Customs tariff number | 8536694040 |
CAS-No. | 7439-92-1 | REACH Candidate List Substance | Lead |
RoHS Compliance Status | Compliant,With Exemption | RoHS Exemption | 6(c) |
SCIP notification number (Austria) | b3032459-1455-48cd-bc5e-e3c0ac561065 | SCIP notification number (Belgium) | 2d7df462-4ea1-4037-ba8d-ae7bdc59ef3a |
SCIP notification number (Bulgaria) | 3ee457d6-dd0c-49b0-a25e-a15ab33a2c11 | SCIP notification number (Czech Republic) | 3c0fb2e2-2807-482a-95b6-fa220367c2fd |
SCIP notification number (Denmark) | 8532e4b3-0c70-407b-8be7-1ec3c6b179f0 | SCIP notification number (Finland) | 6876ca7a-5f2d-40c6-9017-f6067b198fdf |
SCIP notification number (France) | 4885274f-d3e8-4243-a992-fa83c8d9bcda | SCIP notification number (Germany) | 1f5d26bb-c31b-4cc0-a8a6-1e99a42afee4 |
SCIP notification number (Hungary) | f422a96a-b996-4232-9822-a70f8db527b3 | SCIP notification number (Italy) | 69243c11-3c8d-4900-aff7-47ea4b00a4cf |
SCIP notification number (Netherlands) | 44d4002c-27a3-4e75-8ccc-590eec972361 | SCIP notification number (Poland) | 82a163c8-bd3d-4fb1-b7ee-c8971be1557f |
SCIP notification number (Romania) | bcb33303-26b0-4c98-a05c-0b1327eca42a | SCIP notification number (Sweden) | 0a2c9b2e-c54c-40ac-94a5-56962e13a408 |
Ratings per | IEC/EN 60664-1 | Rated voltage (III / 3) | 160V |
Rated impulse voltage (III / 3) | 2.5kV | Rated voltage (III/2) | 160V |
Rated surge voltage (III/2) | 2.5kV | Nominal voltage (II/2) | 320V |
Rated surge voltage (II/2) | 2.5kV | Rated current | 10A |
Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 | Approvals per | CSA |
Rated voltage UL (Use Group B) | 300V | Rated current UL (Use Group B) | 10A |
Rated voltage UL (Use Group D) | 300V | Rated current UL (Use Group D) | 10A |
Rated voltage CSA (Use Group B) | 300V | Rated current CSA (Use Group B) | 10A |
Rated voltage CSA (Use Group D) | 300V | Rated current CSA (Use Group D) | 10A |
Number of poles | 16 | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
Vibration and shock stress for rolling stock equipment | Passed |
Specifications may be subject to change without notice